3500 Kgf Vibration System
The medium range of Shakers is designed online production test schedules of all sectors of industries and special research-oriented testing laboratories.
Automatic pneumatic operated load compensation system employs latest micro-electronics & optical sensors built into the shaker which helps in realising nominal displacement at all payloads.
The shaker’s electromagnet is energized by the solid-state field power supply interlocked electronically to the amplifier console and is placed within the console to save space.
The Solid State, MOSFET/IGBT based, switching type, air cooled, matched with shaker to achieve the rated Sine, Random and Shock testing capabilities. Modular construction, Compatible with all standard Controllers.
Exemplary safety interlocks are logged on to the microcontroller based intelligent logic unit, which is most user-friendly in communicating the system status and operation.
System Performance | Metric | American |
Model Number | EVG 350 | EVG 350 |
Sine Force | 3,500 Kgf | 7,700 lbf |
Random Force | 3,500 Kgf | 7,700 lbf |
Shock Force | 7,000 Kgf | 15,400 lbf |
Frequency Range | DC to 2,800 Hz | DC to 2,800 Hz |
Armature Diameter | 360 mm | 14.1 in |
Armature Material | Magnesium | Magnesium |
Effective Armature Mass | 35 Kg | 77 lb |
Continuous Displacement (peak to peak) | 51 mm/ 63mm (optional) | 2.0 in/ 2.5 in (optional) |
Max Velocity | 1.8 m/sec | 5.9 ft/sec |
Max Acceleration (Sine) | 981 m/s2 (100 `g’) | 100 `g’ |
First Resonant Frequency (±5%) bare table | 2,600 Hz | 2,600 Hz |
Max. Static Payload Capacity | 350 Kg | 770 lb |
Stray Magnetic Field | <10 gauss | <10 gauss |
Cooling Type | Air cooled | Air cooled |
Dimensions (L x W x H) | 1420 x 885 x 1165 mm | 55.9 x 34.8 x 45.8 in |
Shaker weight | 3500 Kg | 7700 lb |
Power Amplifier | ||
Model Number | PA 35SM | PA 35SM |
Rated Power Output | 45 kVA | 45 kVA |
Power Efficiency | >90% | >90% |
Signal to Noise Ratio (SNR) | >70 dB | >70 dB |
Input Impedance | 10 k Ohm | 10 k Ohm |
Input Sensitivity | 4 Vrms | 4 Vrms |
Total Harmonic Distortion in resistive load | Typically 0.5% | Typically 0.5% |
Cabinet Structure | Modular construction, rack mounted | Modular construction, rack mounted |
Safety Protections | Shaker Over Temperature, Shaker Over Travel, Mains Input Over/ Under Voltage, Amplifier Over Temperature, Cooling Air Flow Interlock, Field Fail, Loss of Input | |
Safety Compliance | System complies with EMC, Low Voltage and Machinery Directives as per international safety requirements. |
Note: Above specifications are standard specifications subject to revision to continuous improvement/ developmental activities without prior notice.