7000 Kgf Vibration System

The Water-cooled series Shakers are designed to test of most complex applications including DRDO, Avionics, ISRO, Military electronics and hazardous materials.

The hydrostatic bearing guidance of resin-bonded fiber reinforced armature coil takes care of both high and low acceleration tests supported with the pneumatic compensation for the armature.

Automatic pneumatic operated load compensation system employs latest micro-electronics & optical sensors built into the shaker which helps in realising nominal displacement at all payloads.

The shaker’s electromagnet is energized by the solid-state field power supply interlocked electronically to the amplifier console and is placed within the console to save space.

The Solid State, MOSFET/IGBT based, switching type, air cooled, matched with shaker to achieve the rated Sine, Random and Shock testing capabilities. Modular construction, Compatible with all standard Controllers.

Exemplary safety interlocks are logged on to the microcontroller based intelligent logic unit, which is most user-friendly in communicating the system status and operation.

System Performance Metric American
Model Number EVG 700W EVG 700W
Sine Force 7,000 Kgf 15,400 lbf
Random Force 7,000 Kgf 15,400 lbf
Shock Force 21,000 Kgf 46,200 lbf
Frequency Range DC to 2,000 Hz DC to 2,000 Hz
Armature Diameter 500 mm 19.6 in
Armature Material Magnesium Magnesium
Effective Armature Mass 82 Kg 180.4 lb
Continuous Displacement (peak to peak) 38 mm/ 51mm (optional) 1.5 in/ 2.0 in (optional)
Max Velocity 1.8 m/sec 5.9 ft/sec
Max Acceleration (Sine) 833 m/s2 (85 `g’) 85 `g’
First Resonant Frequency (±5%) bare table 2,000 Hz 2,000 Hz
Max. Static Payload Capacity 800 Kg 1760 lb
Stray Magnetic Field <10 gauss <10 gauss
Cooling Type Water cooled Water cooled

 

Power Amplifier
Model Number PA 70SM PA 70SM
Rated Power Output 120 kVA 120 kVA
Power Efficiency >90% >90%
Signal to Noise Ratio (SNR) >70 dB >70 dB
Input Impedance 10 k Ohm 10 k Ohm
Input Sensitivity 4 Vrms 4 Vrms
Total Harmonic Distortion in resistive load Typically 0.5% Typically 0.5%
Cabinet Structure Modular construction, rack mounted Modular construction, rack mounted
Safety Protections Shaker Over Temperature, Shaker Over Travel, Mains Input Over/ Under Voltage, Amplifier Over Temperature, Cooling Air Flow Interlock, Field Fail, Loss of Input
Safety Compliance System complies with EMC, Low Voltage and Machinery Directives as per international safety requirements.

Note:    Above specifications are standard specifications subject to revision to continuous improvement/ developmental activities without prior notice.